Volume 8, Issue 2 (6-2010)                   IJCE 2010, 8(2): 134-142 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mir Mohammad Hosseini S, Hajimohammadi A, Hajimohammadi A R. The Validity Assesment of Laboratory Shear Modolus Using In-Situ Seismic Piezocone Test Results. IJCE 2010; 8 (2) :134-142
URL: http://ijce.iust.ac.ir/article-1-455-en.html
Abstract:   (15871 Views)

Seismic piezocone device (SCPTu) together with Resonant Column and Cyclic Triaxial test apparatus are

employed to measure small strain shear modulus (G0) of carbonate sandy and clayey soils of southern coasts of Iran.

A large area of southern regions of Iran is formed from clay, silt and sand. In this study, maximum shear modulus that

is derived from both field (by seismic piezocone) and laboratory (by Resonant Column and Cyclic Triaxial) tests on

soil samples from the southern region, indicated a meaningful effect of sample disturbance. Results show that in

laboratory tests, loose samples tend to become denser and therefore exhibit greater stiffness whereas dense samples

tend to become looser, showing a reduction in stiffness. According to the results of the present study, there are narrow

limits of soils shear moduli for which the laboratory tests and the field measurements yield approximately the same

amounts. This limit of shear moduli is about 30-50(MPa) for clay deposits and 70-100 (MPa) for sandy deposits. Since

the shear moduli of soils in small strains can also be computed from the shear wave velocity, also correlations based

on parameters derived from SCPTu test for shear wave velocity determination of sandy and clayey soils of the studied

area are presented. This study shows that shear wave velocity can be related to both corrected tip resistance and total

normal stress. The measurements of the damping ratio and shear module, because of a great disturbance of stiff

deposits during the sampling process and also due to considerable differences between the laboratory and field

results, by the laboratory approaches are not reliable and advised.

Full-Text [PDF 351 kb]   (4051 Downloads)    
Type of Study: Research Paper | Subject: Seismic Geotechnique

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 CC BY-NC 4.0 | International Journal of Civil Engineering

Designed & Developed by : Yektaweb