Showing 2 results for Arjomand
Mahmood R. Abdi, Ali Parsapajouh, Mohammad A. Arjomand,
Volume 6, Issue 4 (December 2008)
Abstract
Clay soils and their related abnormal behavior such as excessive shrinkage, swelling, consolidation settlement and cracking on drying has been the subject of many investigations. Previous studies mainly evaluated the effects of additives such as lime, cement and sand on these characteristics. Initial results indicated that the soil characteristics were improved. However, reportedly in many cases, these additives resulted in a decrease in plasticity and increase in hydraulic conductivity. As a result, there has been a growing interest in soil/fiber reinforcement. The present investigation has focused on the impact of short random fiber inclusion on consolidation settlement, swelling, hydraulic conductivity, shrinkage limit and the development of desiccation cracks in compacted clays. To examine the possible improvements in the soil characteristics, samples consisting of 75% kaolinite and 25% montmorillonite were reinforced with 1, 2, 4 and 8 percent fibers as dry weight of soil with 5, 10 and 15mm lengths. Results indicated that consolidation settlements and swelling of fiber reinforced samples reduced substantially whereas hydraulic conductivities increased slightly by increasing fiber content and length. Shrinkage limits also showed an increase with increasing fiber content and length. This meant that samples experienced much less volumetric changes due to desiccation, and the extent of crack formation was significantly reduced.
M.r. Abdi, S. A. Sadrnejad, M.a. Arjomand,
Volume 7, Issue 4 (December 2009)
Abstract
Large size direct shear tests (i.e.300 x 300mm) were conducted to investigate the interaction between clay
reinforced with geogrids embedded in thin layers of sand. Test results for the clay, sand, clay-sand, clay-geogrid, sandgeogrid
and clay-sand-geogrid are discussed. Thin layers of sand including 4, 6, 8, 10, 12 and 14mm were used to
increase the interaction between the clay and the geogrids. Effects of sand layer thickness, normal pressure and
transverse geogrid members were studied. All tests were conducted on saturated clay under unconsolidated-undrained
(UU) conditions. Test results indicate that provision of thin layers of high strength sand on both sides of the geogrid
is very effective in improving the strength and deformation behaviour of reinforced clay under UU loading conditions.
Using geogrids embedded in thin layers of sand not only can improve performance of clay backfills but also it can
provide drainage paths preventing pore water pressure generations. For the soil, geogrid and the normal pressures
used, an optimum sand layer thickness of 10mm was determined which proved to be independent of the magnitude of
the normal pressure used. Effect of sand layers combined with the geogrid reinforcement increased with increase in
normal pressures. The improvement was more pronounced at higher normal pressures. Total shear resistance provided
by the geogrids with transverse members removed was approximately 10% lower than shear resistance of geogrids
with transverse members.