Showing 78 results for Concrete
Guray Arslan, Muzaffer Borekci, Muzaffer Balci, Melih Hacisalihoglu,
Volume 14, Issue 3 (4-2016)
Abstract
The contribution of concrete to inelastic deformation capacity and shear strength of reinforced concrete (RC) columns failing in shear has been investigated extensively by various researchers. Although RC members are designed to have shear strengths much greater than their flexural strengths to ensure flexural failure according to the current codes, shear degradation of RC columns failing in flexure has not been studied widely. The aim of this study is to investigate the shear degradation of RC columns using finite element analyses (FEA). The results of FEA are compared with the results of experimental studies selected from literature, and it is observed that the lateral load-deflection curves of analysed columns are compatible with the experimental results. Twenty-six RC columns were analysed under monotonically increasing loads to determine the concrete contribution to shear strength. The results of analyses indicate that increasing the ratio of shear to flexural strength reduces the concrete contribution to shear strength of the columns.
Kabir Sadeghi,
Volume 14, Issue 5 (7-2016)
Abstract
A fast converging and fairly accurate nonlinear simulation method to assess the behavior of reinforced concrete columns subjected to static oriented pushover force and axial loading (sections under biaxial bending moment and axial loading) is proposed. In the proposed method, the sections of column are discretized into “Variable Oblique Finite Elements” (VOFE). By applying the proposed oblique discretization method, the time of calculation is significantly decreased and since VOFE are always parallel to neutral axis, a uniform stress distribution along each oblique element is established. Consequently, the variations of stress distribution across an element are quite small which increases the accuracy of the calculations. In the discretization of section, the number of VOFE is significantly smaller than the number of “Fixed Rectangular Finite Elements” (FRFE). The advantages of using VOFE compared to FRFE are faster convergence and more accurate results. The nonlinear local degradation of materials and the pseudo-plastic hinge produced in the critical sections of the column are also considered in the proposed simulation method. A computer program is developed to calculate the local and global behavior of reinforced concrete columns under static oriented pushover and cyclic loading. The proposed simulation method is validated by the results of tests carried out on the full-scale reinforced concrete columns. The application of the “Components Effects Combination Method” (CECM) is compared with the proposed “Simultaneous Direct Method” (SDM). The obtained results show the necessity of applying SDM for nonlinear calculations. Especially during the post-elastic phase, which occurs frequently during earthquake loading.
Mahnoosh Biglari, Iman Ashayeri, Mohammad Bahirai,
Volume 14, Issue 6 (9-2016)
Abstract
In this article, general procedures for vulnerability assessment and retrofitting of a generic seismically designed bridge are outlined and the bridge’s damage criteria for blast resistance are explained. The generic concrete bridge is modeled and analyzed with the finite element technique implemented in ANSYS LS-DYNA environment and explosion threats are categorized into three main levels. Uncoupled dynamic technique is adopted to apply the blast loads on the bridge structure, damage and performance levels are resulted based on quantitatively verified damage mechanisms for the bridge members. The results show that, amongst different loading scenarios, the explosions that happen under deck are more critical comparing to blasts initiating from over deck sources. Furthermore, two retrofitting methods 1) concrete filled steel tube (CFST) and 2) concrete jacket are applied on the bridge columns. The program AUTODYN is used with coupled dynamic analysis of a column to compare the effectiveness of each method. Afterward, more efficient method for a column is applied to the whole bridge and its efficiency is revaluated. It is shown that CFST can decrease concrete spall, scabbing, rotation, displacements and shear forces more than the concrete jacket. Considering the proposed damage and performance levels, the bridge retrofitted with CFST reacts with lower damage level and higher performance level to blast loads.
Behrouz Behnam,
Volume 14, Issue 8 (12-2016)
Abstract
Observations and investigations have proved that using traditional fire curves such as stand-ard fire curves and natural fire curves should be limited to small/medium compartments. In addition, when using the traditional fire curves, a uniform temperature is assumed throughout the compartment. However, for large open compartments, assuming uniform temperature is not compatible with real fires. To overcome this limitation, a non-uniform fire method named as travelling fire is employed as an alternative. A study is performed here on a seismic-damaged large plan 3-story reinforced concrete structure designed to meet the life safety level of performance when exposed to a travelling fire. To draw a comparison, the structural fire analysis is also performed using the traditional methods. The results show a notable difference – while the fire resistance based on the travelling fire is around 91 minutes, it is around 140 minutes when based on a uniform temperature. This shows that the structure studied is more susceptible to failure when subjected to the non-uniform fire than the uniform fire.
Dongdong Zhang,
Volume 14, Issue 8 (12-2016)
Abstract
This paper compares the seismic load of a 5MW wind turbine supported by a 100-m-high prestressed concrete tower calculated via time history analysis and response spectrum analysis using elastic acceleration spectrum provided by the China Aseismic Code for Buildings. With 5% damping ratio, the fixed-based Multi-degree of freedom model and Finite element model considering soil structure interaction are used for response spectrum analysis and time history analysis, respectively. The results indicated that the seismic load calculated by response spectrum analysis is significantly larger than the results associated with the time history analysis method. It implies that the seismic load determined from common building code procedures along with other loads for wind turbine foundation design is too conservative. Within this paper, the effects of damping ratio, horizontal acceleration amplitude, spring stiffness and damping coefficient of foundation on the seismic load of the prestressed concrete wind turbine tower are discussed. It is shown that the seismic load with mode damping ratio for the prestressed concrete wind turbine tower is not significant when compared with traditional tubular steel designs. The maximum moment demand at the base of the tower may be controlled by earthquake loading as the seismic fortification intensity lever is more than seven. The foundation spring stiffness has a immensely impact on the base bending moment and the natural frequency. Finally, seismic load should be considered in more detail when designing wind turbines that are supported by concrete towers, particularly for turbine’s over 100-m tall and located in seismically active zones.
Vahid Broujerdian, Mohammad T. Kazemi,
Volume 14, Issue 8 (12-2016)
Abstract
Complex nature of diagonal tension accompanied by formation of new cracks as well as closing and propagating preexisting cracks has deterred researchers to achieve an analytical and mathematical procedure for accurate predicting shear behavior of reinforced concrete, and there is the lack of a unique theory accepted universally. Shear behavior of reinforced concrete is studied in this paper based on recently developed constitutive laws for normal strength concrete and mild steel bars using nonlinear finite element method. The salient feature of these stress-strain relations is to account the interactive effects of concrete and embedded bars on each other in a smeared rotating crack approach. Implementing the considered constitutive laws into an efficient secant-stiffness based finite element algorithm, a procedure for nonlinear analysis of reinforced concrete is achieved. The resulted procedure is capable of predicting load-deformation behavior, cracking pattern, and failure mode of reinforced concrete. Corroboration with data from shear-critical beam test specimens with a wide range of properties showed the model to predict responses with a good accuracy. The results were also compared with those from the well-known theory of modified compression field and its extension called disturbed stress field model which revealed the present study to provide more accurate predictions.
Hassan Ziari, Parham Hayati, Jafar Sobhani,
Volume 15, Issue 1 (1-2017)
Abstract
In this paper, self-consolidating concrete (SCC) mixtures are considered for airfield concrete pavements. A series of rheological, mechanical, transport and frost action durability tests were conducted on the prepared SCC mixtures with and without chemical air entraining agents (AEA). Mineral admixtures including slag, fly ash, silica fume and metakaolin were included in SCC mixtures. The results showed that application of mineral admixture led to significant improvements on the performance of airfield concrete pavement mixtures. Moreover, the performance of mixtures against frost action upgraded when AEA included in companion with the mineral admixtures.
Kabir Sadeghi,
Volume 15, Issue 1 (1-2017)
Abstract
A nonlinear Finite Element (FE) algorithm is proposed to analyze the Reinforced Concrete (RC) columns subjected to Cyclic Biaxial Bending Moment and Axial Loading (CBBMAL). In the proposed algorithm, the following parameters are considered: uniaxial behavior of concrete and steel elements, the pseudo-plastic hinge produced in the critical sections, and global behavior of the columns. In the proposed numerical simulation, the column is discretized into two Macro-Elements (ME) located between the pseudo-plastic hinges at critical sections and the inflection point. The critical sections are discretized into Fixed Rectangular Finite Elements (FRFE). The basic equilibrium is justified over a critical hypothetical cross-section assuming the Kinematics Navier’s hypothesis with an average curvature. The method used qualifies as a “Strain Plane Control Process” that requires the resolution of a quasi-static simultaneous equations system using a triple iteration process over the strains in each section. In order to reach equilibrium, three main strain parameters (the strains in the extreme compressive point, the strains in the extreme tensile point and the strains in another corner of the section) are used as three main variables. The proposed algorithm has been validated by the results of tests carried out on full-scale RC columns. The application of the Components Effects Combination Method (CECM) is also compared with the proposed Simultaneous Direct Method (SDM). The results obtained show the necessity of applying SDM for the post-elastic phase, which occurs frequently during earthquake loading.
Masoud Ahmadi , Hosein Naderpour , Ali Kheyroddin ,
Volume 15, Issue 2 (3-2017)
Abstract
Concrete filled steel tube is constructed using various tube shapes to obtain most efficient properties of concrete core and steel tube. The compressive strength of concrete is considerably increased by the lateral confined steel tube in circular concrete filled steel tube (CCFT). The aim of this study was to present an integrated approach for predicting the steel-confined compressive strength of concrete in CCFT columns under axial loading based on large number of experimental data using artificial neural networks. Neural networks process information in a similar way the human brain does. Neural networks learn by example. The main parameters investigated in this study include the compressive strength of unconfined concrete (f'c), outer diameter (D) and length (L) of column, wall thickness (t) and tensile yield stress (fy) of steel tube. Subsequently, using the reliable network, empirical equations are developed for the confinement effect. The results of proposed model are compared with recently existing model on the basis of the experimental results. The findings demonstrate the precision and applicability of the empirical approach to determine capacity of CCFT columns.
Patryk Kot, Andy Shaw, Mike Riley, Azlan Shah Ali, Allison Cotgrave,
Volume 15, Issue 2 (3-2017)
Abstract
Concrete flat roof defects such as water leakage present a significant and common problem in large building, particularly in tropical countries, where rainfall is high. To monitor this condition, effective non-destructive test methods are required to detect problems at an early stage, especially hidden defect within the concrete roof, which are critical. This paper presents the potential use of electromagnetic (EM) waves for determining possible leakage of the concrete flat roof as a result of failure of the waterproof membrane layer. This study was assessed, experimentally by investigation of the propagation of EM waves through the roof and their interaction with water. Novel Microwave sensors described in the paper operates in the 6 GHz to 12 GHz frequency range using a Marconi 6200A microwave test set. A range of existing current methods were overviewed and analysed. Results of experimental tests confirmed that microwaves could be used as an alternative non-destructive method for identifying water ingress caused by membrane failure into the concrete roof.
Slawomir Biruk, Piotr Jaskowski,
Volume 15, Issue 2 (3-2017)
Abstract
A formwork is a structure used to contain poured concrete and to mold it to the required dimensions. Different formwork systems provide a wide range of concrete construction solutions that can be chosen to suit the needs of a particular structure. The selection of panels and the design of the formwork layout for concrete structures, especially if the panels are to be reused many times to form different work zones, is one of the most complex tasks in formwork construction. It influences the quality of work, construction time, site safety and cost. The formwork costs account for a significant part of the total costs for concrete works. The problem of the selection and layout of reusable panel forms is solved mainly based on the intuitive judgment of experienced engineers in collaboration with the form system supplier. This study proposes a mixed integer linear programming modeling approach to support the formwork planning process. The problem consists in determining the number and sizes of the panels according to the geometry of the concrete elements in order to minimize the rental cost of wall shuttering in a building divided into work zones that are to be completed in sequence, reusing the chosen panels. The model can be solved using typical software dedicated to mixed integer linear programs. A simple example is used to illustrate the efficiency of the proposed approach, where the formwork rental costs is 7.31% lower than the rental costs of panels and corners optimized without consideration of the reuse in consecutive zones.
Takayoshi Maruyama, Hideaki Karasawa, Shin-Ichiro Hashimoto, Shigeyuki Date,
Volume 15, Issue 2 (3-2017)
Abstract
Pre-cast concrete products are sometimes manufactured in 2 cycles per day with one mold for the purpose of productivity improvement and so forth. In such a case, from the point of view of securing early-time strength which is required at the time of demolding, it is necessary to increase steam curing temperature and then the likelihood of temperature cracking becomes a concern. Moreover, self-compacting concrete (hereinafter refer as “SCC”) is increasingly used to which ground granulated blast-furnace slag is added, in consideration of environment surrounding a plant or operation environment. One choice then is to admix expansive agent in order to prevent cracking due to autogenous shrinkage. However, there is some possibility that high temperature curing required for 2 cycles per day production likely enhances cracking due to expansive agent admixing. In this study, the cause of cracking of large-sized pre-cast concrete products with high amount of expansive agent, in comparison of 1 cycle per day and 2 cycles per day productions was investigated.
As the result, it was confirmed that high temperature steam curing and early demolding of 2 cycles per day production promote thermal stress cracking in contrast to 1 cycle per day production, and at the same time, un expected cracking along main reinforcement is caused by excess expansion due to inappropriate curing of expansive agent.
Alireza Habibi, Keyvan Asadi,
Volume 15, Issue 4 (6-2017)
Abstract
One kind of the irregularities in structures, with considerable effect on seismic performance, is setback in elevation that causes large damage especially in the vicinity of the irregularity. The main objective of this research is to propose and develop drift based index to estimate damage to Reinforced Concrete Moment Resisting Frames (RCMRFs) with setback. For this purpose, first, inelastic dynamic time-history analysis is performed on several frames with different types of setbacks subjected to various earthquake records and damage to them is computed by the Park-Ang damage index. Then two relations between the damage and drift are derived by applying irregularity indices to account for setback effects. It is shown that the proposed damage indices are capable to estimate the damage index of setback frames.
Muhammad Yousaf, Zahid Ahmed Siddiqi, Muhammad Burhan Sharif, Asad Ullah Qazi,
Volume 15, Issue 4 (6-2017)
Abstract
In this study, a comparison is made between force and displacement controlled non-linear FE analyses for an RC beam in flexure with partially developed steel bars. An FE model with slightly unsymmetrical reinforcement was analyzed by applying two-point loading using both force and displacement controlled methods. The responses obtained using ANSYS-13 were validated against available experimental data. Combined comparative display of flexural response of the beam using force and displacement controlled analysis, that has least been addressed in the literature, is given here. Study choses large-deformation-nonlinear plastic analysis scheme, discrete modeling approach for material modeling and program-chosen incremental scheme following Newton-Raphson method. The results show that displacement controlled approach is efficient in terms of time saving and less disk space requirement along with the ability to give falling branch of load-deflection response, if element displacement capacity still exists. Moreover, it gives an early estimate of the load carrying capacity of the structural element along with suitable values of convergence and non-linear solution parameters. However, for a beam with unsymmetrical detailing, force controlled analysis method seems to yield more realistic and practical results in terms of mid span deflection and beam cracking behavior compared with assumed symmetric displacement controlled technique. It also gives true fracture prediction at ultimate load level, which is not true for the displacement controlled method as the computer code forces the model to maintain equal displacements at two load points, falsely increasing the capacity of the beam.
Chayanon Hansapinyo,
Volume 15, Issue 4 (6-2017)
Abstract
This paper presents an evaluation on lateral cyclic behaviors of precast concrete columns using a steel box connection through experimental investigation. The test consisted of one monolithic reinforced concrete column as a reference and five precast concrete columns. All specimens had identical dimensions of 0.25 x 0.25 m2 cross sectional area and 1.7 m in height with a longitudinal reinforcement ratio of 0.0152. Materials used for all specimens were also from the same batch. The study was aimed at understanding the design concept of the steel connecting box and detailing of column reinforcement for avoiding the brittle failure of precast concrete frame buildings. The experimental results show that without premature failure in welding or nut slipping, depending largely on the reinforcement details, the precast system with a steel box connection can be effectively used. Flexural failure mode with a ductile mechanism can be achieved to resemble the monolithic one. With a higher relative stiffness and capacities of the designed connecting box, the precast columns show a higher capacity as the failure section was shifted to an upper level. Hence, it can be said that the proper details of precast concrete columns contain acceptable seismic performances e.g. ultimate capacity, stiffness, energy dissipation, and capacity degradation under repeated loading.
Somayyeh Karimiyan, Abdolreza S. Moghadam, Ali Husseinzadeh Kashan , Morteza Karimiyan,
Volume 15, Issue 5 (7-2017)
Abstract
Among important issues in progressive collapse behavior of a building is tracking down the type and location of the damaged elements. This paper deals with identifying the distribution of collapse from the first element to the entire building due to earthquake loads. Here, 3D collapse propagations in symmetric and asymmetric reinforced concrete buildings are compared using nonlinear time history analyses. The variables of such analyses are earthquake load intensity and the level of in plan one directional mass eccentricity. Results show that collapse distribution is dependent on the degree of asymmetry in building. Some patterns to predict progressive collapse scenarios in similar symmetric and asymmetric buildings are also determined. One main pattern shows that the propagation of collapse is horizontal through the stories, but not vertical through the height of the buildings. Spread of the collapse is independent of the earthquake records also according to the results, damage concentration is larger in places with larger mass concentration.
Dr Mahdi Sharifi, Eng Majid Kamali,
Volume 15, Issue 5 (7-2017)
Abstract
Fiber Reinforcement Concrete is mainly distinguished in their behavior in cracked tension zone which is called tension softening behavior. Wide researchers have been investigated this behavior and present many tensioned softening models. This paper presents a compression between four tension softening models including constant, linear, bilinear and exponential models in flexural behavior. In this study the behavior of rectangular beam section under four/three point bending test have been predicted by iteration procedure. These models has been compared in some parametrical properties. The result of this study shows variety in result for four used models and indicate concern in applied assumptions.
Dr. Kabir Sadeghi, Dr. Fatemeh Nouban,
Volume 15, Issue 5 (7-2017)
Abstract
This paper describes both global and local versions of an energetic analytical model to quantify the damage caused to reinforced concrete (RC) structures under monotonic, cyclic or fatigue loading. The proposed model closely represents the damage to structures and yields a damage index (DI) for the RC members. The model is cumulative and is based on the energy absorbed. The energy under the monotonic envelope curve at the failure of the member is taken as a reference capacity. The data required to apply the model in any given situation or member can be obtained either by numerical simulation or from experimental tests. An analytical computer program was developed to simulate numerically the response of RC members taking into account the nonlinear behavior of the materials and structures involved. The proposed model was verified by comparison with practical tests undertaken by other researchers on over 20 RC columns. The comparison demonstrates that the model provides a realistic estimation of the damage of the RC structural members. The comparison between values of the proposed DI calculated based on experimental test data and numerical simulation results for a cyclic loading case shows that to calculate DI, it is not necessary to perform expensive experimental tests and that using a nonlinear structural analytical simulation is sufficient. The results are also compared to a damage model proposed by Meyer (1988).
Varol Koç, Yusuf Emi̇roğlu,
Volume 15, Issue 7 (10-2017)
Abstract
Minimum reinforcement ratios provided in the standards are remaining at very low levels especially at large systems subject to the effects of earthquake. Thus, arranging the reinforcement ratios intended for preliminary design can provide significant ease and safety in project design phase, and speed and simplicity in the project control phase. Moreover, a more realistic limitation becomes ensured compared to general minimum reinforcement ratios given in the standards. System characteristics which may affect the reinforcement ratios can be specified by general and simple parameters. As the result of many extensive studies, expressions for reinforcement ratios intended for preliminary design which will cover systems having different parameters can be composed. Today, thanks to the development levels of finite elements programs which can perform reinforced concrete modeling, meeting this requirement is much more possible compared to the past. Structure of parameters should neither be very special nor very general. Otherwise, reinforcement ratios intended for preliminary design will either be valid for a single system or they will remain at very low limits such as the minimum reinforcement ratios given in the standards. For this reason, in this study it was tried to follow a route in between these two extreme conditions. Today, it is possible to perform many studies on the systems having different and comprehensive inclusive parameters and to determine practical ratios which will constitute a recommendation for the project designs. For this purpose, an eight storey reinforced concrete system with single spacing whose shear wall cross-section is 25x250cm, column cross-section is 25x30cm, and beam cross-section is 25x50cm was addressed, and its non-linear planary analyses under static earthquake loads were performed through the ANSYS finite elements program for 13 different reinforcement case. The reinforcement ratios to be recommended for the addresses system and similar systems were tried to be revealed. The examined system was arranged as to get the most critical and extreme values for many parameters which can be considered, but it was tried for the reinforcement ratios to be recommended to be valid not only for this system but also for the general system network having similar properties to this system. In the future researches, expressions of general and inclusive preliminary design reinforcement ratios can be obtained as per the results of many studies to be made on systems having different parameters.
Parviz Ghoddousi, Amir Masoud Salehi,
Volume 15, Issue 8 (12-2017)
Abstract
The fresh properties of Self Compacting Concrete (SCC) might be more susceptible to quality and quantity changes of ingredients than conventional concrete because of a combination of detailed requirements, more complex mix design, and inherent low yield stress and viscosity. In spit of the low robustness of SCC, there are a few methods available to assess the SCC robustness that the accuracy of these methods has not been fully agreed. The current study provides an index for SCC robustness based on the rheology parameters. Thus, an experimental program was undertaken to evaluate the robustness of eight selected SCCs. For doing this, water content of each SCC was changed slightly and their fresh and hardened properties were measured. The results indicated that the length of rheology parameters curve due to variation of mixing water is able to assess the SCC robustness that is comparable with combined performance based on the workability tests changes. According to this index, the robustness of SCC increases about 10% by using air-entraining admixture (AEA) and decreases considerably by reduction the paste volume (up to about 5 times). Also, the most appropriate single workability test to assess the robustness is sieve segregation test. Moreover, the scattering of compressive strength results show that there is a level of robustness in fresh state that after that the scattering of results in hardened state can be affected.