Search published articles


Showing 7 results for Buckling

M.m. Alinia,
Volume 2, Issue 4 (12-2004)
Abstract

One main factor in design of panels subjected to axial loading is their buckling behaviour. The design of stiffeners in a metal or composite plated structure is the key factor for safety and weight reduction. This work presents a parametric study on the optimal types and geometrical properties of stiffeners in plates under in-plane axial loads. The results show that flanged type (such as T or L) longitudinal stiffeners increase the normal critical stresses by at least 28% compared to non-flanged stiffener. It is also shown that the optimum geometric properties of stiffeners correspond to the point when the buckling shape of a plate changes from the overall to local mode. Also it is illustrated that for these optimal instances, there always is a linear relationship between the cross-sectional area ratio and the rigidity ratio of the stiffeners to the plates. Finally, Sample relationships for plates having different number of stiffeners are presented.
Sabouri Ghomi S., Kharazi M.h.k., Asghari A., Javidan P.,
Volume 3, Issue 1 (3-2005)
Abstract

Design and construction of efficient and economic Reinforced Concrete (R.C.) Hyperbolic Cooling Towers have driven the engineers toward the design of tall and thin-shell towers which have considerable high slenderness aspect ratio. Consequently, the shell of R.C. Cooling Towers with relative high slenderness aspect ratio is extremely prone to buckling instability due to wind loading. To increase the structural stability or buckling safety factor, one economic approach is to design and construct stiffening rings for the R.C. Hyperbolic Cooling Towers. Despite the research previously performed to determine the effect of stiffening rings on the buckling behavior of the R.C. Hyperbolic Cooling Towers, information resulting in maximum buckling stability is absent considering the optimized utilization of the quantity and dimension as well as the location of this type of stiffeners. In this paper, not only the effect of the stiffening rings on the buckling stability of the R.C. Cooling Tower is studied but also the optimized location,quantity and dimension of the stiffening rings are carried out for a sample RC Cooling Tower. The dimensions of the selected sample cooling tower are in average typical dimensions which are used in the current practice. In this study, finite element (F. E.) analyses has been carried out to define the buckling modes and resistance of this tower due to wind loading for different number of stiffening ring configurations. Based on the conducted buckling analysis, the optimized number, location and dimension of the stiffening rings that maximizes the tower.s buckling stability are defined and the methodology to achieve this information is discussed in this paper.
A. Kaveh, H.a. Rahimi Bondarabady, L. Shahryari,
Volume 4, Issue 3 (9-2006)
Abstract

The main aim of this paper is to extend the recently developed methods for calculating the buckling loads of planar symmetric frames to include the effect of semi-rigidity of the joints. This is achieved by decomposing a symmetric model into two submodels and then healing them in such a manner that the :::union::: of the eigenvalues of the healed submodels result in the eigenvalues of the entire model. Thus the critical load of the frame is obtained using the eigenvalues of its submodels.
A.r. Rahai, M.m. Alinia, S.m.f Salehi,
Volume 7, Issue 1 (3-2009)
Abstract

Concentric bracing is one of the most common lateral load resistant systems in building frames, and are

applied to many structures due to their manufacturing simplicity and economics. An important deficiency in the

bracing members is their irregular hysteretic loops under cyclic loading. In order to overcome this problem, it is

advised to restrain braces against buckling under compression, since buckling restrained frames dissipate a large

amount of energy. One method to restrain braces against buckling is to cover them with concrete. A proper covering

can prevent the core from buckling and provide similar capacities whether in tension or compression which would

produce regular hysteric curves. In this study, the behavior of buckling restrained braces (BRB) has been investigated

by considering different types of surrounding covers. The steel core is encased in concrete with different coverings. The

covering types include steel tubes, PVC pipes, and FRP rolled sheets. Experimental and numerical analyses were

implemented. According to the results, PVC pipes and FRP sheets are suitable alternatives to steel pipes. Furthermore,

the behavior of several types of steel cores was assessed since, applying steel with high ductility promotes the energy

dissipation of the brace. Finally, the effect of the separating layer between the steel core and the concrete on the

performance of bracing was evaluated.


M. Mahmoudi, M. Zaree,
Volume 9, Issue 1 (3-2011)
Abstract

Inelastic deformation of structural components is generally acceptable in seismic design. In such behavior, the strength of structures increases while plastic hinges are formed in members frequently. The strength revealed during the formation of plastic hinges is called "overstrength". Overstrength is one of the important parameters in the seismic design of structures. The present study tries to evaluate the overstrength of the concentrically steel braced frames (CBFs), considering reserved strength, because of members post-buckling. As such, a static nonlinear (pushover) analysis has been performed on the model buildings with single and double bracing bays, different stories and brace configurations (chevron V, invert Vand X-bracing). It has been realized that the number of bracing bays and the height of buildings have a low effect on reserve strength due to brace post-buckling. However, these parameters have a profound effect on the overstrength factor. These results indicate that the overstrength values for CBFs, proposed in seismic design codes, need to be modified.


A. Gholizad, P. Kamrani Moghaddam,
Volume 12, Issue 1 (3-2014)
Abstract

High performance and reliability of refurbish able knee braced steel frames has been confirmed in previous researches trying to get an optimal design for its configuration. Buckling of diagonal member which affects the hysteretic behavior of KBF under cyclic loadings has not been foreseen in previous evaluations of this system. This deficiency can be improved by utilization of adjustable rotary friction damper device (FDD) as knee element. Diagonal element buckling can be prevented considering a suitable value for FDD sliding threshold moment Mf. Lower values of Mf Lower energy dissipation rate in FDD and this leads to an optimization problem. Nonlinear time history analyses have been performed in addition to lateral cyclic loading analyses to evaluate the response of single story KBF subjected to seismic excitation. Optimal Mf in FDD has been chosen according to these analyses results. Roof displacement and acceleration, base shear and diagonal element’s buckling status have been compared in optimally designed KBF and FDD utilized KBF (FKBF) with different configurations. Nonlinear dynamic analyses have been performed for one, four, eight and twelve story frames under different seismic records with several PGAs. More than 60% displacement response reduction has been earned for the FKBF without considerable increase in base shear.
A. R. Rahai, M. Mortazavi,
Volume 12, Issue 4 (12-2014)
Abstract

During the past years the use of buckling restrained braces (BRBs) have had a dramatic growth due to their better performance comparing to conventional braces. BRBs have more ductility and energy absorption capacity by excluding the overall brace buckling. However, even these kinds of braces have some problems restricting their use in some projects, i.e. high tolerance of applying unbonding material, concrete placing difficulties and their weight. Accordingly, many researchers have conducted experiments to find the possibility of shortening or even eliminating the infill material of the braces. The following study has addressed the effect of debonding material friction ratio, shortening the concrete fill, and finally eliminating it if possible, by reshaping the core element with constant section area. The operated analysis has been carried out both numerically and experimentally. ABAQUS finite element software was applied for numerical analysis and the results were verified by an experimental study in two groups of models each including four full-scale brace models. With a constant core section area, results revealed that without the risk of buckling, the concrete cover length could be reduced. With a special core profile, the infill may be fully omitted and the restrainer would be made up of only a steel tube, which may happen without any changes made to the cross sectional area of the core profile.