Search published articles


Showing 2 results for Drying Shrinkage

H. Famili, M. Khodadad Saryazdi, T. Parhizkar,
Volume 10, Issue 3 (9-2012)
Abstract

Self-desiccation is the major source of autogenous shrinkage and crack formation in low water-binder ratio (w/b) concretes

which can be reduced by internal curing. In this paper performance of high strength self consolidating concrete (HS-SCC) with

w/b of 0.28 and 0.33 including autogenous shrinkage, drying shrinkage, compressive strength, and resistance to freezing-thawing

was investigated. Then, for the purpose of internal curing, 25% of normal weight coarse aggregate volume was replaced with

saturated lightweight aggregate (LWA) of the same size and its effects on the material properties was studied. Two modes of

external curing, moist and sealed, were applied to test specimens after demoulding. Autogenous shrinkage from 30 minutes to 24

hours after mixing was monitored continuously by a laser system. The initial and final setting time were manifested as a change

of the slope of the obtained deformation curves. Shrinkage after initial setting was 860 and 685 microstrain (&mu&epsilon) for 0.28 and 0.33

w/b mixtures, respectively. The saturated LWA reduced these values to 80 and 295 &mu&epsilon, respectively. By LWA Substitution the 28-

day compressive strength of 0.28 w/b mixture was reduced from 108 to 89 and 98 to 87 MPa for moist and sealed cured specimen,

respectively. The corresponding values for 0.33 w/b mixture was 84 to 80 and 82 to 70 MPa. Shrinkage of 0.28 w/b mixture

without LWA after moist and sealed cured specimen dried for 3 weeks was about 400 &mu&epsilon. Shrinkage of moist and sealed cured

specimen containing LWA was reduced 9% and 25%, respectively. On the contrary for 0.33 w/b mixture an increase was noticed.

Freezing-thawing resistance was improved by sealed curing, decreasing w/b and substituting LWA.


M. S. Lee, T. S. Seo,
Volume 12, Issue 1 (3-2014)
Abstract

Because thin plate reinforced concrete members such as walls and slabs are greatly influenced by the drying shrinkage, cracks can occur in these members due to the restraint of the volume change caused by drying shrinkage. Therefore, the control of cracking due to drying shrinkage is very important in building construction that the thin plate members are frequently used. However, few researches of estimating shrinkage cracking in RC walls have been executed, and the cracking control design of RC walls has been conducted based on the experience rather than the quantitative design method. In this study, the practical cracking prediction method using equivalent bond-loss length Lb was proposed for the quantitative drying shrinkage crack control of RC wall. The calculated values using proposed method were compared with the experimental results from uniaxial restrained shrinkage cracking specimens and the investigative values from the field study. In general, the results of this method were close to those of the experiment and the field study.

Page 1 from 1     

© 2024 CC BY-NC 4.0 | International Journal of Civil Engineering

Designed & Developed by : Yektaweb