Search published articles


Showing 2 results for Physical Modeling

H. Ghiassian, M. Jalili, I. Rahmani, Seyed M. M. Madani,
Volume 11, Issue 4 (12-2013)
Abstract

The concept of Geosynthetic Cellular Systems (GCS) has recently emerged as a new method in construction of breakwaters and coastal protective structures. The method potentially has significant advantages compared to conventional systems from the standpoint of constructability, cost effectiveness, and environmental considerations. This paper presents the results of physical model testing on the hydraulic responses of GCS structures under wave action. A series of model tests were carried out in a wave flume on GCS models with different shapes and soil types, subjected to various wave characteristics. Horizontal wave forces acting on the models were measured at different elevations. The maximum horizontal force in each test was calculated and compared with conventional formula of predicting wave pressure on breakwaters. The results show that Goda’s equation overestimates the hydrodynamic water pressure on these structures. This can be attributed to the influence of seeping water through the GCS models because of relative permeability of the GCS.
M. Zare, A. Eslami,
Volume 12, Issue 4 (12-2014)
Abstract

Physical modeling for study of deep foundations can be performed in simple chambers (1g), calibration chambers (CC),

and centrifuge apparatus (ng). These common apparatus face certain limitations and difficulties. Recently, Frustum Confining

Vessels (FCV) have been evolved for physical modeling of deep foundations and penetrometers. Shaped as the frustum of a

cone, this device applies steady pressure on its bottom and creates a linear stress distribution along its vertical central core.

This paper presents the key findings in FCV, as developed in AUT. The FCV has a height of 1200 mm, with top and bottom

diameters of 300 and 1300 mm, respectively. By applying bottom pressure up to 600 kPa, the in-situ overburden stress

conditions, equivalent up to 40 m soil deposits, become consistent with the embedment depth of commonly used piles.

Observations indicated that a linear trend of stress distribution exists, and this device can create overburden stress in the

desired control volume along the central core. Moreover, a couple of compressive and tensile load tests were performed on

steel model piles driven in sand with a length of 750 mm, and different length to diameter (L/D) ratios between 8-15.

Comparison between measured and predicted ultimate capacity of model piles performed in FCV demonstrate a suitable

conformity for similar confinement conditions in the field. Therefore, the FCV can be considered as an appropriate approach

for the investigation of piling geotechnical behavior, and the examination of construction effects.



Page 1 from 1     

© 2024 CC BY-NC 4.0 | International Journal of Civil Engineering

Designed & Developed by : Yektaweb