Showing 6 results for Geogrid
H. Ghiassian,
Volume 2, Issue 1 (3-2004)
Abstract
A study of bearing capacity and compressibility characteristics of cohesive soil, reinforced by geogrid and supporting square footing loads has been conducted. The lack of adequate frictional resistance between clay and reinforcing elements was compensated by using a thin sand layer (lens) encapsulating the geogrid sheet. In this way, tensile forces induced in the geogrid were transferred to the bulk clay medium through the sand particles and soil reinforcement was improved Experiments were conduced on two sets of specimens, one set of 1 x 1 x 1 m dimension and the footing size of 19 x 19 cm (series A), and the other set of 0.15 x 0.15 x 0.15 m dimension and the footing size of 3.7 x 3.7 cm (series B). The loading systems for the above specimens were stress controlled and strain controlled respectively. All specimens were saturated and presumably loaded under an undrained condition. The results qualitatively confirmed the effectiveness of the sand lens in improving the bearing capacity and settlement characteristics of the model footing. In series A, the maximum increase in the bearing capacity due to the presence of the sand lens was 17% whereas in series B, the amount of increase was 24%. The percentage reductions in the settlement for these results were 30% and 46% respectively.
S.a. Naeini, R. Ziaie_moayed,
Volume 7, Issue 2 (6-2009)
Abstract
In recent years, soil reinforcement is considered of great importance in many different civil projects. One of
the most significant applications of soil reinforcement is in road construction. Sub grade soil and its properties are
very important in the design of road pavement structure. Its main function is to give adequate support to the pavement
from beneath. Therefore, it should have a sufficient load carrying capacity. The use of geosynthetics in road and
airfield construction has shown the potential to increase the soil bearing capacity. One category of geosynthetics to
particular, geogrid, has gained increasing acceptance in road construction. A geogrid is a geosynthetic material
consisting of connected parallel sets of tensile ribs with apertures of sufficient size to allow strike-through of
surrounding soil, stone, or other geotechnical material. Geogrid reinforcement of sub grade soil is achieved through
the increase of frictional interaction between the soil and the reinforcement. Geogrid have been successfully used to
provide a construction platform over subgrades. In this application, the geogrid improves the ability to obtain
compaction in overlying aggregates, while reducing the amount of material required be removing and replacing.
Relative agreement exists that substantial benefits can be achieved from the inclusion of geogrids within the pavement
systems however, the quantity of the improvement is in relative disagreement. This paper presents the effects of
plasticity index and also reinforcing of soft clay on CBR values. Three samples of clay with different plasticity index
(PI) values are selected and tested without reinforcement. Then by placing one and two layer of geogrid at certain
depth within sample height, the effects of reinforcement and PI on CBR values are investigated in both soaked and
unsoaked conditions. The results shows that as the PI increase the CBR value decreases and reinforcing clay with
geogrid will increase the CBR value.
Arash Nayeri, Kazem Fakharian,
Volume 7, Issue 4 (12-2009)
Abstract
Abstract: This paper presents the results of pullout tests on uniaxial geogrid embedded in silica sand under monotonic and cyclic pullout forces. The new testing device as a recently developed automated pullout test device for soil-geogrid strength and deformation behavior investigation is capable of applying load/displacement controlled monotonic/cyclic forces at different rates/frequencies and wave shapes, through a computer closed-loop system. Two grades of extruded HDPE uniaxial geogrids and uniform silica sand are used throughout the experiments. The effects of vertical surcharge, sand relative density, extensibility of reinforcement and cyclic pullout loads are investigated on the pullout resistance, nodal displacement distributions, post-cyclic pullout resistance and cyclic accumulated displacement of the geogrid. Tell-tale type transducers are implemented along the geogrid at several points to measure the relative displacements along the geogrid embedded length. In monotonic tests, decrease in relative displacement between soil and geogrid by increase of vertical stress and sand relative density are the main conclusions structural stiffness of geogrid has a direct effect on pullout resistance in different surcharges. In cyclic tests it is observed that the variation of post-cyclic strength ranges from minus 10% to plus 20% of monotonic strength values and cyclic accumulated displacements are increased as normal pressure increase, but no practical specific comment can be made at this stage on the post-cyclic strength of geogrids embedded in silica sand. It is also observed that in loose sand condition, the cyclic accumulated displacements are considerably smaller as compared to dense sand condition.
M.r. Abdi, S. A. Sadrnejad, M.a. Arjomand,
Volume 7, Issue 4 (12-2009)
Abstract
Large size direct shear tests (i.e.300 x 300mm) were conducted to investigate the interaction between clay
reinforced with geogrids embedded in thin layers of sand. Test results for the clay, sand, clay-sand, clay-geogrid, sandgeogrid
and clay-sand-geogrid are discussed. Thin layers of sand including 4, 6, 8, 10, 12 and 14mm were used to
increase the interaction between the clay and the geogrids. Effects of sand layer thickness, normal pressure and
transverse geogrid members were studied. All tests were conducted on saturated clay under unconsolidated-undrained
(UU) conditions. Test results indicate that provision of thin layers of high strength sand on both sides of the geogrid
is very effective in improving the strength and deformation behaviour of reinforced clay under UU loading conditions.
Using geogrids embedded in thin layers of sand not only can improve performance of clay backfills but also it can
provide drainage paths preventing pore water pressure generations. For the soil, geogrid and the normal pressures
used, an optimum sand layer thickness of 10mm was determined which proved to be independent of the magnitude of
the normal pressure used. Effect of sand layers combined with the geogrid reinforcement increased with increase in
normal pressures. The improvement was more pronounced at higher normal pressures. Total shear resistance provided
by the geogrids with transverse members removed was approximately 10% lower than shear resistance of geogrids
with transverse members.
A. Asakereh, S.n. Moghaddas Tafreshi, M. Ghazavi,
Volume 10, Issue 2 (6-2012)
Abstract
This paper describes a series of laboratory model tests on strip footings supported on unreinforced and geogrid-reinforced sand
with an inside void. The footing is subjected to a combination of static and cyclic loading. The influence of various parameters
including the embedment depth of the void, the number of reinforcement layers, and the amplitude of cyclic load were studied.
The results show that the footing settlement due to repeated loading increased when the void existed in the failure zone of the
footing and decreased with increasing the void vertical distance from the footing bottom and with increasing the reinforcement
layers beneath the footing. For a specified amplitude of repeated load, the footing settlement is comparable for reinforced sand,
thicker soil layer over the void and much improved the settlement of unreinforced sand without void. In general, the results
indicate that, the reinforced soil-footing system with sufficient geogride-reinforcement and void embedment depth behaves much
stiffer and thus carries greater loading with lower settlement compared with unreinforced soil in the absent of void and can
eliminate the adverse effect of the void on the footing behavior. The final footing settlement under repeated cyclic loading becomes
about 4 times with respect to the footing settlement under static loading at the same magnitude of load applied.
Wen-Chao Huang,
Volume 12, Issue 3 (7-2014)
Abstract
When geogrid reinforcement is used as a treatment method for improving soft subgrade as a roadway foundation, a top layer of subgrade is usually excavated and backfilled with geogrid-reinforced aggregates. This treatment method produces an adequate platform for the planned roadway construction site, where heavy traffic loading is constantly moving. This paper presents a quantitative assessment of subgrade improvement by geogrid reinforcement based on numerical modelling and parametric studies. First of all, the preliminary numerical models were verified by comparing the analysis results with previous studies. Secondly, the major numerical models in this study were assumed to be a simplified simulation of a geogrid-reinforced two-layer system with an aggregate layer above a subgrade layer. The numerical models were applied a quasi-static loading and unloading cycle, in order to monitor the permanent deformation at the surface of the models. Afterwards, thickness of aggregate layer, and subgrade CBR values were varied in order to summarize the outcomes of each case. This approach makes it possible to quantify the effects of geogrid reinforcement and aggregate material in terms of an enhanced California Bearing Ratio (CBR) of a single subgrade clay layer. Results have shown that when the aggregate thickness is up to 450mm, the contribution of enhanced CBR is mostly from aggregate material. However, when the aggregate thickness is about 150mm with a relatively weak subgrade material, the inclusion of geogrid material can contribute about 50% of the enhanced value.