Search published articles


Showing 1 results for Travelling Fire

Behrouz Behnam,
Volume 14, Issue 8 (12-2016)
Abstract

Observations and investigations have proved that using traditional fire curves such as stand-ard fire curves and natural fire curves should be limited to small/medium compartments. In addition, when using the traditional fire curves, a uniform temperature is assumed throughout the compartment. However, for large open compartments, assuming uniform temperature is not compatible with real fires. To overcome this limitation, a non-uniform fire method named as travelling fire is employed as an alternative. A study is performed here on a seismic-damaged large plan 3-story reinforced concrete structure designed to meet the life safety level of performance when exposed to a travelling fire. To draw a comparison, the structural fire analysis is also performed using the traditional methods. The results show a notable difference – while the fire resistance based on the travelling fire is around 91 minutes, it is around 140 minutes when based on a uniform temperature. This shows that the structure studied is more susceptible to failure when subjected to the non-uniform fire than the uniform fire.



Page 1 from 1     

© 2024 CC BY-NC 4.0 | International Journal of Civil Engineering

Designed & Developed by : Yektaweb