Search published articles


Showing 5 results for Base Isolation

M. Mohebbi, H. Dadkhah, K. Shakeri,
Volume 5, Issue 4 (7-2015)
Abstract

In this paper, optimal design of hybrid low damping base isolation and magnetorheological (MR) damper has been studied. Optimal hybrid base isolation system has been designed to minimize the maximum base drift of low damping base isolation system where for solving the optimization problem, genetic algorithm (GA) has been used. In design procedure the maximum acceleration of the structure has been limited, too. To determine the volatge of semi-active MR damper the H2/LQG and clipped-optimal control algorithm has been applied. For numerical simulations, a three-story frame equipped with the hybrid base isolation and MR damper subjected to the scaled El Centro excitation and optimal hybrid system has been designed. Results of numerical simulations have proven the effectiveness of the optimal hybrid control system in controlling the maximum base drift of isolated structure. Also comparing the performance of hybrid, low and high damping base isolation systems has shown that adding MR damper to low damping base isolation system has improved its performance so that the hybrid system has worked better th an high damping base isolation in reducing the maximum base drift. Testing optimal hybrid control system under different excitations has shown its efficiency.
M. Mohebbi, H. Dadkhah,
Volume 7, Issue 3 (7-2017)
Abstract

Semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. In this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (MR) damper has been studied for controlling superstructure acceleration and base drift separately and simultaneously. A multi-objective optimization problem has been defined for optimal design of semi-active base isolation system which considers a linear combination of maximum acceleration and base drift as objective function where Genetic algorithm (GA) has been used to solve the optimization problem. H2/Linear Quadratic Gaussian (LQG) and clipped-optimal control algorithms have been used to determine the desired control force and the voltage of MR damper in each time step. For numerical simulation, a four-story base isolated shear frame has been considered and for different values of weighting parameter in objective function, optimal semi-active base isolation system has been designed under various design earthquakes. The results show that by using base isolation system and supplemental MR damper, the superstructure acceleration and base drift can be suppressed significantly. Also, it has been concluded that by selecting proper values for maximum acceleration and base drift related weighting parameters in objective function, it is possible to mitigate the maximum acceleration and base drift simultaneously. Furthermore, semi-active control system has worked successfully under testing earthquakes regarding design criteria.


M. Mohebbi, H. Dadkhah,
Volume 9, Issue 1 (1-2019)
Abstract

Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, the base stiffness and the weighting parameter of H2/linear quadratic Gaussian control algorithm, which is used to determine the desired control force, have been considered as the design variables and different earthquake records have been considered as design earthquakes. First, the optimum values of these variables under each of the considered earthquakes have been determined by using the genetic algorithm and then, an optimum control system has been designed with multiple earthquakes-based design approach. The defined design objective is minimizing the peak base drift while the peak inter-story drift has been constrained. For numerical simulation, smart base isolation system is designed for controlling a four-story shear frame. The results show that when the control system designed for a specific earthquake is subjected to another earthquake, difference between the performance of this control system and the optimal case under that earthquake is considerable. Hence, the specific earthquake-based design approach is an inappropriate design procedure for smart base isolation. Also, it has been found that control system designed based on multiple earthquakes-based design approach shows effective performance in controlling the response of structure under a wide range of earthquakes.
M. Mohebbi, H. Dadkhah,
Volume 10, Issue 1 (1-2020)
Abstract

In this paper, a design method is proposed for base isolation system under blast loading that this method is based on transforming design problem into an optimization problem. Genetic algorithm has been employed to solve the optimization problem whereas base isolation system properties have been considered as design variables and a linear combination of base drift and inter-story drift has been defined as objective function. A sensitivity analysis has been also conducted to investigate the effect of base isolation system properties on the blast performance of isolated structure. For numerical simulation, base isolation system is designed using the proposed method for controlling the response of an eight-story nonlinear shear-type building frame under blast loading. It has been found from the results that base isolation system is an effective control system under blast loading that its performance is dependent on the base isolation system characteristics especially the base mass. The optimization results also show that base isolation system designed using the proposed method is a well-designed control system for mitigating the blast response of structure and the proposed design method can be considered as an effective design approach under blast loading.
A. Ghaderi, M. Nouri, L. Hosseinzadeh, A. Ferdousi,
Volume 14, Issue 2 (2-2024)
Abstract

Seismic vibration control refers to a range of technical methods designed to reduce the effects of earthquakes on building structures and many other engineering systems. Most of the recently developed methods in this area have been investigated in vibration suppression of buildings structures each of which have advantages and disadvantages in dealing with complex structural systems and destructive earthquakes. This study aims to implement two of the well-known passive control systems as Base Isolation (BI) and Mass Damper (MD) control as a hybrid control scheme in order to reduce the seismic vibration of tall tubular buildings in dealing with different types of earthquakes. For this purpose, a 50-story tall building is considered with tubular structural system while the hybrid BI-MD control system ins implemented in the building for vibration control purposes. Since the parameter tuning process is one of the key aspects of the passive control systems, a metaheuristic-based parameter optimization process is conducted for this purpose in which a new upgraded version of the standard Gazelle Optimization Algorithm (GOA) is proposed as UGOA while the Chaos Theory (CT) is used instead of random movements in the main search loop of the UGOA in order to enhance the overall performance of the standard algorithm. The results show that the upgraded algorithm is capable of conducting better search in dealing with the optimal hybrid control of structural systems.
 

Page 1 from 1     

© 2024 CC BY-NC 4.0 | Iran University of Science & Technology

Designed & Developed by : Yektaweb