Volume 16, Issue 4 (December 2020)                   IJEEE 2020, 16(4): 524-535 | Back to browse issues page


XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shadpey S, Sarlak M. An Intelligent Anti-Islanding Scheme for Synchronous-Based Distributed Generation Using Reduced-Noise Morphological Gradient. IJEEE 2020; 16 (4) :524-535
URL: http://ijeee.iust.ac.ir/article-1-1378-en.html
Abstract:   (3496 Views)
This paper presents a pattern recognition-based scheme for detection of islanding conditions in synchronous- based distributed generation (DG) systems. The main idea behind the proposed scheme is the use of spatial features of system parameters such as the frequency, magnitude of positive sequence voltage, etc. In this study, the system parameters sampled at the point of common coupling (PCC) were analyzed using reduced-noise morphological gradient (RNMG) tool, first. Then, the spatial features of the RNMG magnitudes were calculated. Next, to optimize and increase the ability of the proposed scheme for islanding detection, the best features with a much discriminating power were selected based on separability index (SI) calculation. Finally, to distinguish the islanding conditions from the other normal operation conditions, a support vector machine (SVM) classifier was trained based on the selected features. To investigate the power of the proposed scheme for islanding detection, the results of examinations on the various islanding conditions including system loading and grid operating state were presented.  These results show that the proposed algorithm reliably detect the islanding condition within 32.7 ms.
Full-Text [PDF 1316 kb]   (1573 Downloads)    
  • A novel non-communication-based intelligent islanding detection scheme is proposed which is based on an effective simple digital filter being robust to the environmental noises.
  • In the proposed algorithm, the points of the signal (such as voltage, active power, etc.) with an irregularity are highlighted and, then be used for islanding detection.
  • To improve the performance of the proposed scheme, the separability index has been used to select the most valuable features.
  • The proposed scheme is capable of islanding detection in synchronous-based distributed generation systems in situations with the least exchanged power between the DG resources and the distribution system.

Type of Study: Research Paper |
Received: 2018/11/08 | Revised: 2019/09/27 | Accepted: 2019/10/02

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Creative Commons License
© 2022 by the authors. Licensee IUST, Tehran, Iran. This is an open access journal distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) license.