Volume 5, Issue 4 (December 2009)                   IJEEE 2009, 5(4): 253-260 | Back to browse issues page

XML Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Shahnazari M, Vahedi A. Accurate Average Value Modeling of Synchronous Machine-Rectifier System Considering Stator Resistance. IJEEE 2009; 5 (4) :253-260
URL: http://ijeee.iust.ac.ir/article-1-220-en.html
Abstract:   (12017 Views)
An accurate average value model of synchronous machine-rectifier system considering the effect of stator resistance is derived in this paper. A proper voltage-behind-reactance synchronous machine model without any approximations is used for the generator that allows effective calculation of commutation displacement angle. All rectification modes of the rectifier are studied. A detailed switching model is implemented and validated against experimental measurements. The described average value model is evaluated through comparison of detailed simulation results and average model in time domain.
Full-Text [PDF 264 kb]   (4013 Downloads)    
Type of Study: Research Paper | Subject: modeling of Electrical Machinery
Received: 2009/12/12 | Revised: 2009/12/12 | Accepted: 2013/12/30

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

Creative Commons License
© 2022 by the authors. Licensee IUST, Tehran, Iran. This is an open access journal distributed under the terms and conditions of the Creative Commons Attribution-NonCommercial 4.0 International (CC BY-NC 4.0) license.