Showing 5 results for Microgrids
F. Namdari, M. Parvizi, E. Rokrok,
Volume 12, Issue 1 (3-2016)
Abstract
Integration of distributed generations (DGs) in power grids is expected to play an essential role in the infrastructure and market of electrical power systems. Microgrids are small energy systems, capable of balancing captive supply and requesting resources to retain stable service within a specific boundary. Microgrids can operate in grid-connected or islanding modes. Effective islanding detection methods are essential for realizing the optimal operation of microgrids. In this paper, a new passive islanding detection method is presented according to the change rate of DG’s voltage over active power index. This technique has been applied on inverter-based and synchronous-based microgrids. The efficiency of the proposed method is verified through a comprehensive set of simulation studies carried out in Matlab/Simulink.
E. Alizadeh, A. M. Birjandi, M. Hamzeh,
Volume 12, Issue 4 (12-2016)
Abstract
This paper proposes an autonomous and economic droop control scheme for DC microgrid application. In this method, a cost-effective power sharing technique among various types of DG units is properly adopted. The droop settings are determined based on an algorithm to individually manage the power management without any complicated optimization methods commonly applied in the centralized control method. In the proposed scheme, the system retains all the advantages of the traditional droop method while minimizes the generation costs of the DC microgrid. In the proposed method, all DGs are classified in a sorting rule based on their total generation cost and the reference voltage of their droop equations is then determined. The proposed scheme is applied to a typical DC microgrid consisting of four different types of DGs and a controllable load. The simulation results are presented to verify the effectiveness of the proposed method using MATLAB/SIMULINK software.
E. Alizadeh, A. Motie Birjandi, M. Hamzeh,
Volume 13, Issue 4 (12-2017)
Abstract
This paper proposes a decentralized control technique to minimize the total operation cost of a DC microgrid in both grid-connected and islanded modes. In this study, a cost-based droop control scheme based on the hourly bids of all participant distributed generators (DGs) and the hourly energy price of the utility is presented. An economic power sharing technique among various types of DG units is adopted to appropriately minimize the daily total operation cost of DC microgrid without a microgrid central controller. The DC microgrid may include non-dispatchable DG units (such as photovoltaic systems) and dispatchable generation units. Unlike other energy management techniques, the proposed method suffers neither from forecasting errors for both load demand and renewable energy power prediction modules, nor from complicated optimization techniques. In the proposed method, all DGs and the utility are classified in a sorting rule based on their hourly bids and open market price, and then the droop parameters are determined. The simulation results are presented to verify the effectiveness of the proposed method using MATLAB/SIMULINK software. The results show that the proposed strategy is able to be implemented in various operation conditions of DC microgrid with resistance to uncertainties.
M. Khajevand, A. Fakharian, M. Sedighizadeh,
Volume 16, Issue 3 (9-2020)
Abstract
Using distributed generations (DGs) with optimal scheduling and optimal distribution feeder reconfiguration (DFR) are two aspects that can improve efficiency as well as technical and economic features of microgrids (MGs). This work presents a stochastic copula scenario-based framework to jointly carry out optimal scheduling of DGs and DFR. This framework takes into account non-dispatchable and dispatchable DGs. In this paper, the dispatchable DG is a fuel cell unit and the non-dispatchable DGs with stochastic generation are wind turbines and photovoltaic cells. The uncertainties of wind turbine and photovoltaic generations, as well as electrical demand, are formulated by a copula-based method. The generation of scenarios is carried out by the scenario tree method and representative scenarios are nominated with scenario reduction techniques. To obtain a weighted solution among the various solutions made by several scenarios, the average stochastic output (ASO) index is used. The objective functions are minimization of the operational cost of the MG, minimization of active power loss, maximization of voltage stability index, and minimization of emissions. The best-compromised solution is then chosen by using the fuzzy technique. The capability of the proposed model is investigated on a 33-bus MG. The simulation results show the efficiency of the proposed model to optimize objective functions, while the constraints are satisfied.
Seyed Masoud Barakati, Farzad Tahmasebi,
Volume 19, Issue 3 (9-2023)
Abstract
Increasing the penetration of distributed generation (DG) systems in power systems has many advantages, but it also has problems, including interference with the proper functioning of the protection systems. This problem is severe in microgrid systems that contain many DGs. Overcurrent relays are one of the most critical protection equipment of protection systems. The DG sources significantly change the characteristics of fault currents and the protection designs as well as the coordination of overcurrent relays. This paper proposes a coordination method for directional overcurrent relays with dual adjustment to resolve the interference problem in the protection system of a microgrid in the presence of distributed generation sources based on the electronic power converter (inverter). This is done by considering the curve of different standard characteristics according to the IEC60255 standard in two operating modes, the grid-connected and islanded. A genetic optimization algorithm is used to reduce the total operating time of the relays. The simulation results verify the effectiveness of the proposed coordination method. The results show that the protection coordination scheme with dual adjustment relays and the use of combined characteristic curves can significantly reduce the operating time of the total relays.