Showing 4 results for Statcom
A. Kumar, P. Kumar,
Volume 15, Issue 4 (12-2019)
Abstract
This paper presents the three topologies of three-phase four-wire DSTATCOM for reduction of harmonics, reactive power compensation, increasing power factor, which occur due to a nonlinear load, environment problem and polluted grid. The performances of the above topologies have been compared for the magnitude of source current, power factor improvement, DC-link voltage regulation, and total harmonic distortion. This paper presents a novel work for the new young scientist /industrialist who working in the improvement of power quality in the grid. This paper helps to provide the application, designing constraints of shunt active filter in many fields. The First topology which is used in this paper is the three-phase four-wire four-pole voltage source converter based DSTATCOM. The second is the three-phase four-wire with three-leg voltage source converter based DSTATCOM with T-connected transformer and the third topology is the three H-bridge voltage source converter based DSTATCOM. The T-connected transformer in the second topology has been used to reduce the rating for voltage source converter. Synchronous reference frame theory based controller has been proposed to the generation of the reference current. Reference current generated from the synchronous frame theory is processed to hysteresis current controller loop which produces switching pulses for VSC based DSTATCOM. All these topologies have been implemented in MATLAB /Simulink platform by using different types of loading conditions such as resistive and power electronics load.
S. R. Hosseini, M. Karrari, H. Askarian Abyaneh,
Volume 15, Issue 4 (12-2019)
Abstract
This paper presents a novel impedance-based approach for out-of-step (OOS) protection of a synchronous generator. The most popular and commonly used approaches for detecting OOS conditions are based on the measurement of positive sequence impedance at relay location. However, FACTS devices change the measured impedance value and thus disrupt the performance of impedance-based relay function. In this paper, the performance of synchronous generator OOS protection function connected to the transmission line in the presence of a static synchronous compensator (STATCOM) is investigated. Moreover, an analytical adaptive approach is used to eliminate the effect of STATCOM. This approach requires only the remote bus voltage and current phasors to be sent to the relay location via a communication channel. Simulation results show that STATCOM changes impedance trajectory and causes the incorrect operation of OOS relay. Furthermore, the proposed approach corrects the relay mal-operation and improves the accuracy of OOS impedance-based function when the STATCOM is used in the system.
S. R. Hosseini, M. Karrari, H. Askarian Abyaneh,
Volume 17, Issue 1 (3-2021)
Abstract
In this paper, a novel approach based on the Thévenin tracing is presented to modified conventional impedance-based out-of-step (OOS) protection. In conventional approach, the OOS detection is done by measuring positive sequence impedance. However, the measured impedance may be change due to different factors such as capacitor bank switching and reactive power compensators that it can cause the relay to malfunction. In this paper, first, an on-line Thévenin equivalent (TE) approach based on the recursive least square (RLS) is presented. Then, a protection function is developed based on online network Thévenin equivalent parameters to correct the measured impedance path. The main feature of this method is the use of local voltage and current measurements for Thévenin equivalent estimation and OOS protection. The performance of the proposed method is investigated by simulation of synchronous generator OOS protection function in the presence of a static synchronous compensator (STATCOM). The simulation results show that, STATCOM changes the impedance path and can cause the incorrect diagnosis of OOS relay. Furthermore, the proposed method corrects the impedance path and improves the accuracy of OOS impedance-based function when the STATCOM is installed in system.
S. Shabani, M. Asadi, A. Zakipour,
Volume 19, Issue 1 (3-2023)
Abstract
In this paper, parasitic capacitors and common mode voltage (CMV) are modeled in a delta connection multilevel cascaded STATCOM. In high frequency and high voltage applications the parasitic capacitors play important role in common mode voltages. In this paper, parasitic capacitors and CMV are modeled in a multilevel cascaded STATCOM and also parasitic currents are calculated, then a method will be proposed to reduce the effects of the parasitic capacitors. The values of parasitic capacitors are calculated by finite element software. Finally, a delta connection 13-level cascaded STATCOM with parasitic capacitors will be simulated in MATLAB Simulink and then simulation results will be presented.