Mosleh M E, Besmi M R. Sensitivity Analysis and Stray Capacitance of Helical Flux Compression Generator with Multi Layer Filamentary Conductor in Rectangular Cross-Section. IJEEE 2012; 8 (1) :55-67
URL:
http://ijeee.iust.ac.ir/article-1-405-en.html
Abstract: (6765 Views)
This paper presents an approach to calculate the equivalent stray capacitance (SC) of n-turn of the helical flux compression generator (HFCG) coil with multi layer conductor wire filaments (MLCWF) in the form of rectangular cross-section. This approach is based on vespiary regular hexagonal (VRH) model. In this method, wire filaments of the generator coil are separated into many very small similar elementary cells. By the expanded explosion in the liner and move explosion to the end of the liner, the coil turns number will be reduced. So, the equivalent SC of the HFCG will increase. The results show that by progress of explosion and decrease of the turns’ number in the generator coil total capacitance of the generator increases until the explosion reaches to the second turn. When only one turn remains in the circuit, a decrease occurs in the total capacitance of the generator.
Type of Study:
Research Paper |
Subject:
Special Electric Machines Received: 2011/05/20 | Revised: 2014/09/30 | Accepted: 2012/02/04